Prevost Community Forums

Find answers, ask questions, and connect with our
Prevost Community around the world.

  • Water heater thermostat

    Posted by Per on April 12, 2016 at 3:24 pm

    Is there an adjustable thermostat for the electric heat for the water heaters, and where is it located? Trying to heat water with electric results in lukewarm water. Motoraid and Webasto works fine. Our old coach had no problem giving us hot water just on electric. I checked the circuit breaker of course.

    Corey replied 10 years, 4 months ago 4 Members · 5 Replies
  • 5 Replies
  • Jim

    Member
    April 12, 2016 at 6:26 pm

    There is a chance that you only have one of your water heaters working. I would pull the cover on the units with power off..Then check for voltage at each unit, and test the heat element. If your units thermastats are adjustable it will be behind that cover as well.

  • Per

    Member
    April 12, 2016 at 7:30 pm

    Per,

    I agree with Jeff, you may only have one working. We’ve never run out of hot water even with back to back showers and you know how the ladies like those Hollywoood showers.

  • Per

    Member
    April 12, 2016 at 8:58 pm

    Tom,

    Turns out Jeff was right. I opened up the el connection panels, and it turned out the reset switch on the top unit had popped. Running a test right now, but now I have AC flowing to the bottom unit.

    Really appreciate it, Jeff!

    BTW, the top unit has a thermostat. It was set to 125–I upped it to about 140, we like our water hot!

  • Archived

    Member
    April 13, 2016 at 1:14 am

    Per

    I was having trouble with my water heater reset being tripped a while back. The short story is it turned out the motor aide loop had two busted solenoid valves that was allowing 200 degree engine coolant to heat the water in the water heater to 200 degrees. My over temp reset trips at 190.

    So when I stopped driving, I had hot water. When the water in the water heater cooled off, I could not use the electric heat to warm up the water due to the over temp thermostat being tripped. I hope your problem is just a weak over temp thermostat.

  • Corey

    Member
    April 13, 2016 at 8:29 am

    Michael, we’ll have to see how it works on the next trip. When we stopped on the last trip, the hot water was not overly hot. Electronics tend to be temperamental, but if keeps happening, I’ll look into your suggestion.

    P.S. You should post a picture of your coach; I’ve seen some beautiful CC conversion of your vintage, such as the one we saw in June last year at GSR in Reno.

Log in to reply.