Prevost Community Forums

Find answers, ask questions, and connect with our
Prevost Community around the world.

  • Generator shut down malfunction

    Posted by Ron on March 4, 2019 at 3:52 pm

    When I stop the generator from the drivers area, it shuts down until it almost stops completely. Then the starter engages making a gear-to-gear sound. It keeps repeating this scenario until I turn off the remote start switch on the generator.

    The only thing I have noticed is the light in the “start gen” switch flickers in sync with the engagement of the starter.

    Any ideas?

    Archived replied 7 years, 5 months ago 3 Members · 2 Replies
  • 2 Replies
  • Archived

    Member
    March 4, 2019 at 5:17 pm

    Switch at Generator is in auto? Inverter setting on gen start is set to??

  • Kathy

    Member
    March 5, 2019 at 9:57 am

    Gen switch was set for remote start and inverter is set for auto start.

Log in to reply.