An Electrical Issue: Generator? Inverter?
I am not sure if the root cause of this is the generator, Trace inverter or some where else but I will place this in the electrical thread. I do not know where to start so I will go plum around the mulberry bush and give you the sequence of events as I know them.
We have had a very hot and humid week in Tulsa, Oklahoma. We were without shore power so the generator ran 205 hours straight with no problems. Sunday night I ran to the bus to changed into work clothes to take the tent down and noticed the front air was off. I opened the panel door and discovered the #2 inverter was inverting and the #1 inverter was in error and shut completely down and was not inverting. Both red lights on #1 inverter were solid. Those red lights are “Error” and “Over Current.” The generator was still running but not showing power at the inverters.
The generator or shore power usually flashes a green light for a moment and then goes solid to indicate the power is in good. The green light was not on at all even though the generator was running.
I turned #1 inverter off and back on to clear the error but it did nothing. I went to the generator menu and moved it from “ON” to “Off” and also “Auto” and the generator kept running. I left it in “Auto” and hit the stop button and the generator shut down.
I went to the inverter bay to make sure the fans were on and inverter #1 felt hot to the touch. I was afraid it was fried or something since the controls would not make it function or clear the error. The only error that read “Yes” was the generator start error. No one was in the bus when this happend but as far as I know the generator had never been off.
I was in a hurry, flustered and hot so what I did next was a rookie mistake. I did not turn off the loads on side #1 so my front AC, water heater and fridge were left on with the generator in “Auto” mode. The inverter was not inverting so nothing on that side was running. Some time in the next 90 minutes the generator came back on. I suppose the amp draw called for it since I left the front AC and water heater on. The inverter was in error and shut down but evidently it still called for the generator to come online.
(Keep in mind, this is a Vantare so EVERYTHING 110 runs through the inverters.)
When I got back to the bus, the generator was running but neither inverter was showing any power from the generator and the #1 inverter was still in error. I went to the Flying J to get diesel, empty tanks and get my wits about me. Thank God for good working bus AC that cooled us off.
First I set the generator to “OFF” mode at inverter #1 and then I shut the generator down again manually. Once the generator was off, I cycled the inverter itself to “OFF” and back “ON” and the solid red error lights went away and it started inverting.
I did not know if the inverters would have power if plugged in to shore power or not. It was too late to call anyone so I came onto to our next stop in Wichita and plugged into solid shore power.
I arrived in the night and plugged into shore power and the inverters showed power and everything was fine. Some time in the night it occured to me that something was interupted between the generator and the inverters. I checked and sure enough the main 70 amp breaker at the generator was tripped.
I will take the panel lid off and check for loose connections. Beyond that, I am stumped. Could be a weak breaker although it does not feel weak and I do not ever remember flipping it off and on. It is probably 21 years old. I think I will replace it with a 100 amp for good measure. JOKING!
I have not turned the generator back on to see if the inverters will switch over to it as they should. I have no reason to believe they will not but it is very hot here this week and I do not want to go back to the situation of last night with no power at all.
Starting Saturday I will need the generator all week for another scorcher in OKC. What else should I consider? An inverter problem? A generator problem? Loose wires some where else? A fluke from excessive heat? I am open to ideas.
Davy