  • Posted by Archived on February 19, 2015 at 6:48 am

    Moire and more I am learning about issues with air systems. For several years the number of problems reported have been rising. Now with bitter cold affecting coaches I can say with almost 100% accuracy if your air system has not been maintained, and you are using your coach in the very cold conditions you are going to experience problems.

    The culprit is moisture. Even the smallest amount getting past the dryer and wet tank can affect air system parts. That moisture is corrosive and it affects steel springs, the bore in the Norgren valves, and it will often contribute to a build up of sludge in the Norgrens and other valves. And if it is cold enough the moisture freezes and the systems do not work.

    If the moisture does not come from the engine driven compressor side of the system, it can come from the aux compressor which has water traps downstream that need draining.

    What makes moisture in the air system such an issue is that when problems occur diagnosis is almost impossible because the system does not act or function as intended and nothing seems to make sense. At that point the only way to determine why something is not working correctly is to verify the operation of every component one at a time. That gets expensive and very time consuming.

    Archived replied 11 years, 9 months ago 1 Member · 1 Reply
  • 1 Reply
  • Archived

    Member
    February 20, 2015 at 8:13 am

    I want to add to my previous comments.

    A member had a serious issue with his coach because it would not maintain the ride or driving height. Attempts to diagnose it over the phone failed. In fact nothing made sense. As it turns out it appears someone had worked on the coach and in doing so reconnected the air hoses to the Norgren valves that supply air to the ride height valves backwards.

    With the previous post in mind and now learning of this problem some critical points have been driven home.

    First, we know moisture in our air systems creates problems that defy diagnosis and make no sense. One example was many years ago an owner could not get his coach to lower in the front. It turns out the controlling Norgren was water logged and it could not move internally.

    Second, anytime anyone tries to diagnose issues the thought process involves following a logic path based on how the system operates. That fails when the system is modified because at that point the only solution is to go through the process of verifying the system configuration. That is impossible over a phone, via the forum or using emails. Without a degree of luck or a lengthy step by step verification of every wire or air hose, the solution is very time consuming and involves checking every terminal and fitting.

    My point is if you want to eliminate or at least minimize what can be very time consuming and expensive repairs keep your air system well maintained, and if anyone works on the system make absolutely certain they fully understand the system.

Log in to reply.