Aux. Compressor making air dryer purge
I am new to PC but have owned a coach for long enough to know that I cannot keep everything working at the same time. Its always something.
When I park the bus to stay overnight and use the auto level feature to level the coach, I pull the parking brake, switch the motor to high idle and wait until all the solenoids purge off and stop making noise. Because of my OCD, I switch the level button back to ride height partially filling any airbag that completely dumped so Im not leaving the coach with a bottomed out bag (not enought to make the coach unlevel again) then turn off the engine.
As soon as I switch the button to ride hieght the aux. tank pressure goes down and the aux compressor kicks on. The compressor starts to fill the aux. tank back up to about 95lbs then I hear the air dryer purge (key is off, engine is off). The compressor keeps running and the dryer purges again and again so i just shut the compressor off.
In the morning I turn the aux compressor back on, start the bus, turn the high idle on (exactly 2 minutes after starting to make sure the turbo is well oiled) and wait for the coach to reach ride height. Everything is good to go.
Basically, when Im not trying to level the bus and just park it, the aux compressor cycles and shuts off normally. Is there a valve that is not closing all the way causing air to back feed to the dryer or what?
To be more specific, its the main dryer with the spin on desiccant filter located above the drive axle that is purging. Not the Norgren water trap or anyting in the steering compartment.
Log in to reply.