Delay to fill primary air on start up.
We use to our coach just about every weekend. Therefore it sits for about 5 days at a time. I leave it at ride height with the primary & secondary at 120 psi (the comp cut out). When I return they are both right around 105-110psi. I have no problem with that.
Lately, I have noticed on start up after 5 days of sitting, when I start the coach to build air back up, the secondary will fill along with the aux tank normally. The primary will stay right where it was for about 30 seconds after the air dryer purges then you hear a rush of air in the rear and it jumps to 120 psi just like the other tanks.
I always make sure any moisture is drained (monthly) by draining the tanks in order, I have a new dryer filter (3 months old) and a new governor. Basically, everything is working properly on the air system except for a slight delay to fill the primary tank that is getting longer on start up after the coach sits. No sign of problems out on the road.
Is is there a check valve I’m hearing that is going bad or sticking causing the primary tank to not fill right away with the others? Is it a double check valve? I hear something releasing in the rear like a valve!
Something is sticking.
Thanks!
Log in to reply.