Air system overhaul
Having replaced all air bags and brake chambers, my next project is a complete overhaul of the air system. Mine was a 1998 model seated coach, built in 1997, so it’s time. I’ve found surprising evidence of poor maintenance while it was in commercial service, so I’m assuming no component has been replaced that didn’t fail completely. It is long overdue for replacement of all Norgren valves and probably much more. Two years ago, after finding black oil in the air from the air dryer bleed at the rear fill port and a few tablespoons of what looked like chocolate milk at the wet tank drain, I replaced the engine-mounted air compressor and governor along with the air dryer element and check valve assembly. I’ve never found any moisture when bleeding the accessory air tank, but I did find a Norgren valve in the kneeling circuit frozen and a trace of oil at the exhaust ports of all three ride height valves. I solved the frozen Norgren valve problem by disabling the kneeling system (installed new air lines from the front air bags direct to the front ride height valve). If a lady can’t step high enough to enter the coach at normal ride height, she’s too old for me anyhow. 🙂 Now I’m ready to troubleshoot the entire system and replace components as necessary. Without a leveling system of any kind, my coach air system should be simpler than most.
The air system bleeds down almost completely within a couple hours. A single major leak that depletes the system that fast should be easily heard, but with my loss of hearing from a career in aviation, it would just about have to blow my socks down as I walk around the coach for me to notice. What I can hear is the AD-9 air dryer singing continuously. A professional medical stethoscope against the side of the canister indicates the sound from the system charging, steady-state or leaking down is coming from inside more than at the valve at the bottom. The system passes a DOT pre-trip check if I’m doing it right, but when I air the coach up to 115 PSI, then bleed the wet tank, the gauges show 110/110/105 (F/R/A) by the time I get to the driver’s seat. A half hour later, they’re at 60/60/60 and after an hour, 30/30/40.
Now, after all this history, here are some questions the group can perhaps answer for me: What’s the best approach to take when troubleshooting the system from scratch? Since I can’t tell if the sound the air dryer is making is caused by multiple leaks beyond it or air bleeding backwards through it, is it reasonable to begin by capping off the supply from the wet tank to the primary tank and airing up the system? It seems like that would test the integrity of the compressor, governor, wet tank and air dryer. If that was successful, I’d reconnect the primary and cap off the delivery port of the secondary tank to eliminate the entire aux system and see if the system still holds pressure. In my mind, that would take all aux leaks out of the equation and point the finger at pressure protection valves, check valves or brake system leaks. Only after making the heart of the system leak free would I then start on the Norgrens and the smaller leaks. Am I on the right track? I have no experience working on the air system, so I’ll appreciate any guidance or suggestions any of you might offer.
Log in to reply.