  • Fresh Water Tank Monitor

    Posted by Tim on January 15, 2017 at 8:42 pm

    The last few times I hit the “Auto-Fill” to fill the fresh water tank, it stopped at 78%.

    Is there anyway to adjust the Auto-Fill, or would this be a sensor issue on the Fresh water?

    Dick replied 6 years, 10 months ago 10 Members · 15 Replies
  • 15 Replies
  • tom

    Member
    January 15, 2017 at 10:20 pm

    Which fresh water monitor system do you have on tank ? Electronic or air pressure ?

    AL

  • Archived

    Member
    January 15, 2017 at 10:46 pm

    Tim,

    The Marathon owner’s manual says that the auto-fill will only fill the tank to 79% and is shut off by a sensor located on the tank at that level. The auto-fill valve has been known to fail to completely close, so it is a good idea to add a pressure control valve (40psi) to the fresh water supply inlet hose and turn off the manual water supply valve after filling the tank. If you want to fill the tank to completely full, you can finish filling through the blue manual fill cap located in the upper right hand corner of the water bay.

  • Archived

    Member
    January 16, 2017 at 6:24 am

    Tim,

    Since the autofill is controlled by Techlink, you may not be able to adjust the percentage. Mine doesn’t work, so I put in a manual switch for filling and shut it off when the water comes out the overflow assuring 100% full. You may want to talk to Leon.

  • AL

    Member
    January 16, 2017 at 6:22 pm

    Al,

    I don’t know if I have an electronic or air pressure. How would I find this out.

    Chuck,

    I do have a pressure regulator on my fresh water hose.

    Tom,

    Leon is certainly an option or I could re-boot my tech link system since I installed an “on/off” switch. I could always fill they the gravity fill side. I just like my water going they the whole house filter first to avoid any sediment getting in the fresh water tank.

  • Dick

    Member
    January 16, 2017 at 8:51 pm

    Tim,

    My problem is the Node Relay for the auto-fill, so temporarily, I ran power to the fill solenoid with a switch taking the auto-fill out of the loop. It works just like the auto-fill, city water running through the filter.

  • John

    Member
    January 16, 2017 at 8:54 pm

    Tim…..behind this circle cover are 3 small pumps. This access cover is removable where pumps sit on a ledge.

  • Dick

    Member
    January 16, 2017 at 9:04 pm

    Al,

    Are the pumps like the pump for an aquarium? I have the same set up and was wondering what the pumps

    are for.

  • John

    Member
    January 16, 2017 at 9:49 pm

    Yes, aquarium pumps, 0ne (1) each for gray,black, fresh water. Pumps can be rebuilt with available kit. I found a complete pump on e-bay for spare.

    This was operating system on my 2000 Marathon #591. Have no idea when this set up was changed.

  • Jerry

    Member
    January 16, 2017 at 9:54 pm

    Thanks Al, one more mystery solved.

  • Archived

    Member
    January 17, 2017 at 6:18 am

    Mines an 02 and doesn’t have the pumps.

  • Mike

    Member
    January 17, 2017 at 6:48 pm

    Yep, but ’01 doesn’t have those pumps.

  • Jim/Chris

    Member
    January 17, 2017 at 9:05 pm

    Tim I have the aquarium pumps as well and have had them work on twice with no luck. I talk with Bob at Marathon FT Worth and he is going to install the same system that is on the new Marathons. It is 10 pads that mount on the outside of the tank and can, supposedly sense the slightest pressure changes inside the tank and read out in 10% increments. Once the new sensors are on the tanks, they get calibrated to use the tech link in the bus, and hopefully fix my system never reading tank levels.

  • Bernie

    Member
    January 19, 2017 at 11:07 am

    Is your tank metal or plastic? Our monitor quit working and we would like to replace it without having to mess with an internal sensor. I checked into the See-Level system, but it only works on plastic tanks. If this system works on metal tanks, can you find out the manufacturer? Thanks!

  • Archived

    Member
    January 22, 2017 at 9:17 pm

    My tanks are definitely plastic tanks, which as you said the system, I believe only works on the polyurethane tanks. I will let you know if it works as advertised. I take in in next week to have it installed.

  • Dick

    Member
    October 21, 2019 at 8:42 pm

    Mark,

    I am in the process of installing See-Level tank monitors on our tanks. I would

    like to know how you have yours wired in. I am putting one in the bathroom so

    we can have a pump switch there. We do not have a pump switch there now.

    Any info on how the displays are wired and where and how you get the

    momentary pump switch to work with the 110 volt water pump.

    Thanks,