  • Inverter over temp

    Posted by Archived on April 12, 2015 at 8:17 pm

    Just got back from an overnight at 2 rivers landing where everything worked fine But as I cleaning the coach inside and out today I noticed lower than normal house battery voltage and when I looked at the remote panel the over temp error light was on. It was then realized I did not hear the inverter internal fan running.

    I rolled the bumper down ( house batts and inverters are in the spare tire compartment) and put a fan on the inverter casing. It cooled down and started charging again.

    Its a Heart Fredom 458 2500 watt unit part of my dinosaur collection. I’ll call inverter service Monday to get their view on repair.

    other opinions and comments are welcomed.

    Archived replied 11 years, 7 months ago 3 Members · 8 Replies
  • 8 Replies
  • Archived

    Member
    April 13, 2015 at 6:09 am
  • Archived

    Member
    April 13, 2015 at 6:48 am

    Joe,

    I think all inverters need to be kept clean and all need some supply of cooling air. On a previous coach mine were located under the bed so I could sense when the internal fans were operating. I could hear them cycle on and off. But the coach was also supplied with ductwork to, between and from the inverters that had additional fans that also drew cool air through the inverters.

    I learned that I had to periodically access the inverters which required some disassembly of the bed, so I could pull them, open them up and vacuum any accumulated dust and lint. I kept a spare fan just in case, but never had to use it. My current coach has a fan that runs continuously to draw cool air through the compartment in which the inverters are mounted. Heat is the enemy on a lot of things relating to our coaches.

  • Archived

    Member
    April 13, 2015 at 4:35 pm

    Jon: I’m surprised it doesn’t bug you that the fan runs all the time. That’s the way mine came also with inverters in the #2 compartment on the port side. After replacing a worn out fan, I installed a thermostatic control so that the fan would only operate from about 75-80F upward. The coach is stored plugged in with that bay door open and the fan is unnecessary probably 5 months of the year.

  • Archived

    Member
    April 13, 2015 at 4:45 pm

    I hear the noise in my garage as “white” noise. It doesn’t bother me. I cannot hear it when we are in the coach, and I would rather not add one more thing in the loop to fail. I have a fan that can fail, and adding a switch adds another potential failure point on something I consider a critical system.

  • Bernie

    Member
    April 13, 2015 at 8:21 pm

    I did the same as Joel on my Liberty’s, added thermostats because the compartment fans were 120v hard wired to the inverters. My Marathon has thermostats for the inverter fans. I just figure the fans will last longer not running full time.

  • Larry & Diane

    Member
    April 13, 2015 at 9:26 pm

    When I got my Legendary, the fans were burned out (2). They were replaced and have been fine since. I too have a thermostat to turn them on when it gets to about 85 degrees or so. I can hear them outside, but not really when inside the coach.

  • Archived

    Member
    April 14, 2015 at 2:30 pm

    My fan that failed is the one internal to the inverter. You guys make a good point about a fan in the battery / inverter compartment. I don’t have one, only a screened opening in the bottom of the spare tire compartment. I may look into adding a fan.

  • Archived

    Member
    April 14, 2015 at 4:21 pm

    Good idea. The internal fan is obviously a critcal part of the inverter, but what good does it do if the air it draws through the inverter is already too warm. A fan drawing in fresh air provides the internal fan a better, cooler supply.