Vantare DC Configuration
Okay, now
that I’ve seen the Vantare schematics, dated 99, I can see where some confusion might come from
and can see a couple of things I would change. As I’ve said before, it was great to see the
use of buss bars for the battery cables.
Why this is not common practice makes no sense. Yes, it will cost an extra $100 in parts and
another hour or so in labor, but with
the initial cost of these coaches, what is a couple hundred bucks.First, the
house bank. Yes, it is in fact one 24V
battery bank made up of batteries numbered one through eight. It may appear to be two banks given the
batteries are split between two locations and there is a 12V and 24V buss bar
and cut-off switches labeled 12V and 24V.The first
house bank change I would make is that both inverter temperature sensors MUST
be on the same battery. The worst case
installation of the temperature sensor is exactly what I see here. That would be one sensor on each 12V half of
the bank. Why this is problematic is
that the current being drawn from each half bank may be very different. The equalizer is responsible for keeping both
halves close, but it has a window of acceptable voltage on each half bank. So, they won’t be exactly the same. I would advocate what I do and that’s
configure your chargers so that only one is ever on and occasionally switch
chargers. Unfortunately, as feature rich
as the Trace inverter/charger is there doesn’t seem to be a mode where you can
have the charger off and still support automatic switching to inverter power
with the loss of commercial and generator power. The next best thing is what some of you have
already done and that’s setting the maximum charge current to the lowest
possible setting on one charger.My biggest
concern, based on this schematic and what some of you have stated, is that I
don’t see adequate circuit protection. I
hope the 12V and 24V cutoff switches are collocated with the left and right
half bank of batteries. This would mean
that the positive battery cables are contained such that they can be adequately
protected against short circuits from cable movement and chafing. If this is where the switches are then I
would have expected to see fuses rated at no more than what the battery cables
or cutoff switches (whichever is less) can handle located immediately on the
output of the switches. The closest protection
(breakers) are at the distribution panel and these don’t protect all loads
directly connected to the 2 buss bars.
There’s no protection on the wires feeding the equalizer, generator
starter, the generator boost connection to the chassis battery, alternator, and
battery monitor. With the smart things I
see done by Vantare, I can’t believe they skimped on circuit protection, which
is what is illustrated. Maybe, in
practice they did install protective devices.
Besides the protection I recommended at the 12V and 24V switches, you
should have protected devices as close to the current generating source as
possible (buss bars, alternator, battery isolator, and chassis battery). The only exception allowed in the automotive
industry is the battery to starter connection.
In your application, you can’t guarantee protection of the physical battery
cable coming from the chassis and house banks to the generator starter, so it
too should be protected at the chassis battery and house battery (at the buss
bar). There is also an exception if the
appliance and current source are collocated such that the cable/wire is totally
protected and that the appliance has circuit protection at its power input.I have three
concerns on the chassis battery system.
One I already mentioned and that’s the lack of protection on the cable
going to the generator boost switch. Another
one is the Guest charger. I tried to
find the manual on the charger, but didn’t find one. I’m confident that the 12V charging circuit
should be disconnected from the chassis battery. It makes no sense and it probably drives the equalizer
and 24V charging circuit nuts. The
chassis battery bank is a single 24V bank.
Yes, it’s half tapped to support 12V loads and the equalizer is there to
ensure each half of the bank is equally drained or charged.The other
chassis battery bank concern is where loads are connected. To get the most out of the batteries they
should be drained and charged as equally as possible. That means all 12V loads should be tapped
from battery #10 and all 24V loads to battery #12. The 12V equalizer connection is correct but
the 12V generator boost connect is not. The 24V charger and 24V chassis connections
are correct, but the 24V equalizer connection is not. You also want to limit the number of physical
connections on any battery terminal, which may have driven why these
connections were done this way. With
this in mind, I would leave the generator boost connection where it is given
how rarely it would be used. I would definitely
move the 24V equalizer connection given its critical function to the entire
bank. I would move and protect the 24V
charger connection to the 24V connection on the equalizer. Although Vanner discourages this, the charger
wire is a relatively small gauge and would be supported over the much larger
equalizer cable to the battery bank.Thanks for
the drawings,
Log in to reply.