Over the years I have tried to track generator fuel consumption for planning purposes. It is not an exact science because assumptions have to be made.
The most confidence in consumption was obtained when I was able to fill prior to an extended period of use, and refill immediately following its use at a truck stop less than 2 miles away. In that instance the generator ran 171 hours and consumed 71 gallons for about .415 GPH.
In other instances I had more driving between extended use of the generator so more precise estimates were not available but consumption was estimated to be no more than .5 GPH.
In the above two examples most of the power (and fuel consumed) was to keep batteries charged plus run a couple of A/Cs, the HW tank, and occasional use of the grill, range, TV, and lighting.
This past week I was able to put 66 hard hours on the generator. It was hot out with temps at 92 degrees, I ran 4 A/Cs all the time (they cycled obviously), and was an energy hog using lights. HW tank, grille, range, microwave, aux compressor, water pump, etc. I saw 40 plus amps per leg often so the generator had a good workout.
Unfortunately there was about 550 miles of driving involved so my guess as to how much fuel was burned by the generator was influenced by how many MPG I was getting while driving. I have a range I know represents the minimum MPG and the likely highest MPG so at best I can only come up with a range of consumption for the generator. For the 66 hour period the range with the generator loaded as heavily as I could make it appears to be somewhere between .6 and .7 GPH.
My 20 KW generator output never got above 50 amps per leg, stayed at 40 plus amps per leg a lot of the time and on occasion was as little as 20 amps per leg.
The reason this information is valuable to me is that when I have extended dry camping periods with a lot of generator use I can make some reasonable assumptions regarding fuel needs. I think this last week running the generator loaded as much as I could possible get it represents a worst case situation and only when dealing with a lot of high temps. The more reasonable estimate however is going to be in the range of .5 GPH.
The generator was run from around 6 AM to around 9 or 10 PM every day so it was not controlled by auto-start.