  • Generator Starting Issues

    Posted by Rodney on May 22, 2016 at 7:57 pm

    I have a Martin Generator in my 1990 Marathon Conversion. I have replaced all the relays in the generator relay box plus the ones in the panel on the main floor. I can start the generator by holding the start button either on the generator or on my panel above. I then have to jump the starter. Since this has been happening for a while, I have a remote starter installed. It seems everything is working except for the start to get it’s signal.

    Does anyone have any ideas on what could be the issue stopping the generator to start?

    Archived replied 10 years, 5 months ago 3 Members · 3 Replies
  • 3 Replies
  • Archived

    Member
    May 22, 2016 at 8:13 pm

    Sounds like a starter solenoid bad?

  • Bill

    Member
    May 23, 2016 at 7:52 pm

    I agree with Jerry.

    Bill S.

  • Archived

    Member
    May 31, 2016 at 8:19 pm

    The reason I didn’t investigate the solenoid sooner was that I had just replaced it last year. The previous owner had left a starter for the generator in the bus. I had it checked out. Starter was toast, but the solenoid worked. Replaced the solenoid and all was well. Not sure what caused my solenoid to go bad in a year.